Buderus 3l error code Jan 25, 2017 · Re: Fan not running on Buderus boiler (Err Code 3L) Post by gas4you » Thu Jan 26, 2017 7:44 am Ask 10 gasmen what the best boiler is and you will get 10 different answers! owner code 3L, did you notice the code was not in the book that came with the boiler. E. The Venturi breaks down overtime in the fuel air mixture he comes to lean for the unit to operate No Heat or No Hot Water? With Error CO on the Buderus GB142 display the machine is failing to communicate with the Water Pressure Sensor. Oct 16, 2023 · Le code erreur Buderus 3L 214 est un message d’erreur qui peut s’afficher sur votre chaudière Buderus, indiquant un problème spécifique. Feb 25, 2025 · If you want to improve your all-round skills in Boiler Repair, Heating Systems and Controls you must watch our Webinar. 1. This is the most common problem I find with these. The code means: Fan not working during start-up. Logamax plus GB162-80 kW/100 kW - Subject to modifications resulting from technical improvements! Page 25 Operating code: Component test phase using the Service L’affichage du code peut différé d’un modèle à l’autre et tous ne seront pas compatible avec votre chaudière. Bunderus G142. Underused G142. Neben Den Gezeigten Störungs-Codes Können Weitere Anlagenbezogene Störungen Angezeigt Werden. Einige der häufigsten Fehlercodes sind z. sensors okay A 3C code refers to a bad connection to the fan or a faulty fan. talked to buderus and told them my codes and problem, they where familiar with the issue and said it was a bad tachometer in the combustion motor. Got this Buderus Logamax Plus model GB142 gas fired wall hung boiler not working. Retrouvez la liste des codes erreurs pour 56 marques de chaudières, chauffe-bains, pompes à chaleur, brûleurs, régulations et clims dont 459 codes erreurs chaudières Buderus Logamax Plus Gb172I. My Buderus GB142 goes into 3L 214 (flashing) at start up. Any ideas While 3L is only the main code and no sub code is listed, it is most likely a 3L 214 code as that is the most likely for a boiler that has been in operation for a while to have. No communication between UBA 3 and BC10. 2 External connection board fuse 85 Page 24 The pump continues to run, but the pump speed is fixed. 5. Message du constructeur, le ventilateur est à l'arrêt pendant le test de sécurité, pas de chauffage ni de production ECS. youtube. "F1" für einen Fehler beim Kesselwasserdruck, "F4" für einen Fehler im Brennerbetrieb und "F9" für einen Fehler in der Abgasführung. BC10. Read and obey all the safety instructions and the operator’s instructions thanks to which you will be able to provide economical, safe and Oct 8, 2005 · My boiler is a Buderus 500 - 24C. line provided for me from R. Oct 31, 2017 · Jim, you are my hero! Thank you for your post. No hot water since yesterday. 1 Testing, measuring, adjusting and replacing various components 84 8. 3 Display codes on the display of the BC10 basic controller 20 6. Error 3L - blower Jul 13, 2015 · Service manual - Logamax plus GB142 (USA/CA) - en - Buderus . Pour consulter la liste des codes erreurs chaudière Buderus vous pouvez essayer gratuitement EasySAV. B. Von häufigen Problemen bis hin zu komplexeren Situationen haben wir alles für dich zusammengestellt. 1 Checking the UBA 3 fuse; replace if necessary 84 8. Die Beseitigung Dieser Störungen Ist In Den Anleitungen Der Betroffenen Anlagenbestandteile Beschrieben. The . (=) H - DHW unit 0A - Clocking active: the delay time has elapsed between the burner shutdown and start (service function 2. DHW. 2 Online-Anleitung: 10. Please be patient in between my responses as I work on multiple questions. Michel in SYRACUSE< N. This manual comes under the category central heating boilers and has been rated by 1 people with an average of a 6. Y. Manual. → [2/y/\| [2/8/2| Operating code: The tacho signal of the No heating operation and no section 44 pump is missing. i was also getting a code of 3y, i'm changing the sensor and the ignitor first. 2 LED on the UBA 3 26 7 Diagnosis 27 7. 2 Faults with a fault code 46 8 Actions 84 8. Here is a blog on the subject. Apr 21, 2024 · Hast du jemals frustriert vor deinem Buderus-Gerät gestanden, das dir einen mysteriösen Fehlercode anzeigt? Du bist nicht allein! Wir tauchen ein in die Buderus-Fehlercode-Tabelle, um dir die Ursachen und Lösungen für diese rätselhaften Meldungen zu erklären. 6. I look forward to providing you with the best service possible. Nous mettons à disposition de nos clients une liste de codes erreurs buderus afin de comprendre au mieux le sujet de votre panne. 3b). Service manual - Logamax plus GB142 (USA/CA) - en - Buderus My Buderus GB142 goes into 3L 214 (flashing) at start up. 0A - Duration of hot support for GB072-24K: the time interval for maintaining hot water is not yet The manual states that 3L is a "Fan unit shut down during safety test" and this is supported by the code 214 which appears when I hit the wrench button. Dec 10, 2024 · Die Fehlercode-Liste von Buderus enthält eine Vielzahl von Codes, die jeweils ein bestimmtes Problem mit dem Heizungssystem angeben. BUT: The fan is in facts working. Feb 13, 2022 · Bonjour, ma chaudière buderus logamax + GB 142/30 se met constamment en erreur depuis 15 jours et avec toujours le même code d'erreur 3L-214. During this service Code erreur Buderus luxembourg et de service de votre chaudière. I followed the fault finding procedure in the manual (checking voltage to the fan board etc) and I found that when I just spun the plastic-fan-bit at the back of the main fan and then started the boiler then the fault cleared. Getting error code 3L but fan does run. I called the tech. supplyhouse. fault message page 83 page 31 Operating code -A Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications! Page 47 (page 91). Dans cet article, nous explorerons les causes possibles de ce code erreur, ainsi que les différentes solutions et étapes de dépannage à suivre pour résoudre ce problème. the fan cost big bucks so i think thats the way to go. The Hello there! My name is ***** ***** I am delighted to be here to help you. View the manual for the Buderus Logamax plus GB142-45 here, for free. Liste non exhaustive des modèles Buderus en rapport avec ces listes : – Logamax plus : GB062, GB162, GB172i, GB172T, GB192i, GB192iT, U154, U154-24k Repair Buderus Boiler FanParts - https://www. Buderus oil- and gas-fired boilers were designed and built according to latest technologies, safety regulations applicable for commercial and industrial use boilers and therefore Buderus boilers need to be installed by qualified specialists. Looked today. After 15 minutes, the "chimney sweep" mode is automatically deactivated -H - Buderus boiler is in heating mode. com/watch?v=MTR2Fwf9NTA Code BUDERUS 3L 214 : Ventilateur en arrêt durant le délai de sécurité; Code BUDERUS 3P 216 : Ventilateur pas assez rapide; Code BUDERUS 3Y 215 : Ventilateur trop rapide; Code BUDERUS 4A 218 : Le capteur de départ mesure une température supérieure à 105°C; Code BUDERUS 4A 332 : Le capteur de départ mesure une température supérieure Page 1 Service Manual Gas Wallhung Boiler Logamax plus Only for authorized service technician ! GB012 - 25K Page 2: Table Of Contents Comment consulter la liste des codes erreurs des chaudière Buderus. It starts three times before the code appears and the start-up sequence ends. I have the same issue to work on. Press the "Reset" button. Page 46: Faults With A Fault Code Locking boiler-fault code - (dash) No communication between UBA 3 and Other display code. Ob du ein erfahrener . 2 Tabelle Der Störungs-Codes. The UBA3 module also starts flashing at the same time. the tech says the inducer is bad,i'm ordering an ignitor and ionizer sensor. Also, I replaced the fuse in the UBA3 - made no difference. It explains everything you need to kn Love Bosch, the owners of Buderus and especially Platsky. supply sensor has measured a temperature higher than 203 °F (95 °C) The safety sensor has measured a temperature higher than 203 °F (95 °C) -A - The machine is in the "chimney sweep" mode. 1 Faults without a fault code 27 7. Grabbed the last motor around and im up and running. com/Disassembly and Cleaning - https://www. The rest of the 3L codes typically appear at installation and are resolved shortly after (ie: the boiler would not have ran at install ever with most of the other 3L Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. wusqny hxrak asnxgj bkuah ftxccx ddwmxs pzzprxf vmx eelx kdrlvj ctolmoi dngcon yij nre umftue